Single-phase oil transformers, designed for pole-mounted applications, are widely used in electrical distribution networks, particularly in rural and suburban areas. Single phase oil transformers for pole are crucial for stepping down high-voltage electricity from distribution lines to a lower voltage suitable for residential and small commercial use.

 

Vienas fāzes eļļas transformatori polam

 

Vienas fāzes eļļas transformatori polamApraksts

 

Single-phase oil transformers, designed for pole-mounted applications, are widely used in electrical distribution networks, particularly in rural and suburban areas. Single phase oil transformers for pole are crucial for stepping down high-voltage electricity from distribution lines to a lower voltage suitable for residential and small commercial use.

Pole transformers have two main functions. One is voltage conversion. The main function of a single-phase oil-immersed transformer is to step down the high voltage electricity from the distribution network to a lower usable voltage, usually 11,000 volts (11kV) to 240 volts (V). The other function is cooling and Izolācija . Eļļai transformatora iekšienē ir divējāda loma, atdzesējot iekšējās sastāvdaļas un nodrošinot nepieciešamo izolāciju, lai nodrošinātu, ka transformators darbojas efektīvi un droši dažādos apstākļos .

Single-phase oil-immersed transformers for pole-mount applications are an integral component in power distribution systems, especially in areas where electricity needs to be efficiently transmitted over long distances. Their rugged design, efficiency, and durability make them a reliable choice for powering homes, businesses, and agricultural operations in a variety of environments.

 

Ar stabu uzstādīts transformators

 

Galvenie atribūti

Nozarei raksturīgas atribūti

Produkts

Vienfāzes eļļas pildīts polis, kas uzstādīts transformators

Fāze

Viens

Spoles numurs

Autotransformers

Citi atribūti

Izcelsmes vieta

Džejjanga, Ķīna

Modeļa numurs

Vienfāzes transformators

Nominālā jauda

No 10kVA līdz 333kva

Augstspriegums

34,5kV un zemāk

Zemspriegums

120/240/277/480V

Biežums

50/60Hz

Standarta

IEC, ANSI, IEEE, CSA

Vektoru grupa

II 0, ii6

Materiāls

Alumīnijs/varš

Pieteikums

Lauku enerģijas režģis, attālie kalnainie apgabali, izkaisītie ciemati, lauksaimniecības ražošana, apgaismojums, enerģijas patēriņš, dzelzceļš, pilsētas enerģijas tīkls

Ierakstīt

Ar eļļu iegremdēts transformators

Iezīmēt

Zems zaudējums

 

Šī tabula ir parastā pola uzstādītā transformatora . standarta parametrs Ja jums ir nepieciešami citi ietilpības un sprieguma līmeņi, lūdzu, sazinieties ar transporti, lai iegūtu precīzus tehniskos parametrus un piedāvājumus .

Zemāk specifikācijas ir paredzētas tikai atsaucei .

Ietilpība

(KVA)

η(%)

ε(%)

Io (%)

Pamata zaudējums

(W)

Vara zaudējums

(W)

Dimensija (mm)

Eļļa (L)

Kopējais w . t

(kg)

W

D

H

10

97.2

3

1.9

45

180

440

520

940

30

100

15

97.3

3

1.8

58

215

450

530

970

30

130

25

97.5

2.8

1.7

82

295

500

580

980

40

180

37.5

97.7

2.6

1.6

110

400

520

600

1000

40

220

50

98.1

1.9

1.5

140

490

540

630

1060

45

280

75

98.2

1.8

1.4

200

700

590

670

1100

55

380

100

98.3

1.7

1.3

260

900

680

680

1120

60

450

167

98.4

1.6

1.2

450

1500

710

800

1190

80

580

250

98.5

1.5

1.1

650

2250

980

950

1350

215

980

333

98.6

1.4

1

800

3000

1040

960

1400

240

1100

 

Testa vienums

√ Tinuma pretestības tests

√ Izolācijas rezistences tests

√ sprieguma koeficienta kļūdas tests

√ īssavienojuma pretestības tests

√ bez slodzes zuduma (jaudas) tests

√ Slodzes zuduma (jaudas) tests

√ inducēts sprieguma izturība

√ Atsevišķa avota sprieguma izturība

√ spiediena integritātes testa tests

product-1440-1080

 

25kva vienfāzes eļļas piepildīti ar polu uzstādītie transformatora izmēri un svara detaļas

product-750-528

 

75kva vienfāzes eļļas piepildīti ar polu uzstādītie transformatora izmēri un svara detaļas

product-750-527

 

167kva vienfāzes eļļas piepildīti ar polu uzstādītie transformatora izmēri un svara detaļas

product-750-528

 

Vienfāzes eļļas pildīta pola uzstādīta transformatora diagramma

product-750-635

 

Polta uzstādītie transformatora attēli

 

product-750-563
product-750-563
product-750-563
product-750-563

 

Ar stabu uzstādīts transformatora iepakojums

 

product-750-562

 

Bieži uzdotie jautājumi (FAQ)

 

J: Kāda ir dzelzs kodola loma transformatorā?

A: Dzelzs kodols samazina magnētiskā ceļa nevēlēšanos plūst magnētiskai plūsmai . Mīkstā dzelzs kodolam ir augsta caurlaidība, un tas nodrošina pilnīgu primārās spoles magnētiskās plūsmas savienojumu ar sekundāro spoli .}}}}}}}}}}}}}}}}}}}}}

J: Kādi faktori ietekmē uz polu piestiprinātā transformatora kalpošanas laiku?

A: Mitrums, apkārtējā temperatūra, augstums, putekļi un piesārņotāji var mazināt izolācijas īpašības un dzesēšanas efektivitāti . transformatori skarbā vidē bez atbilstošas ​​aizsardzības pieredzes paātrināta novecošanās un paaugstināta termiskā un elektriskā sprieguma .}}}}}}}}}}}}}}}}}}}

J: Kādi ir faktori, kas ietekmēs transformatora dizainu?

A: Transformatoru izvēle un lielums ietver transformatora pamata parametru, piemēram, primāro un sekundāro spriegumu, KVA, tinuma savienojuma, jaudas koeficienta, dzesēšanas metodes, tinuma vadītāja materiālu, montāžas izkārtojuma, efektivitātes un efektivitātes un frekvences . veidus, montāžas izvietojumu, efektivitāti un efektivitāti.

 